Home›Products›HYLINE-K

Quarter-turn pneumatic

HYLINE-K Rack and Pinion Actuators

Double-acting pneumatic. 15 sizes. 9.2 Nm to 3,509 Nm at 6 bar.

HYLINE-K turns quarter-turn valves with an opposed-piston rack and pinion, powered in both directions. Aluminium or stainless steel bodies, a choice of seals and coatings, and ISO 5211 and NAMUR interfaces let you match each actuator to the valve and the site.

Get a priceDownload the data sheet

HYLINE-K double-acting pneumatic rack and pinion actuator

3,509Nm

Peak torque at 6 barFrom AKD-270, the largest size. Up to 4,679 Nm at 8 bar.

15sizes

From 9.2 NmAKD-032 to AKD-270, on ISO 5211 flanges F03 to F16.

3bodies

Aluminium or stainlessAluminium alloy, 304 or 316 stainless steel.

1million

Cycles testedEvery size is tested to 1 million cycles.

Overview

Positive powered movement in both directions

An opposed-piston rack and pinion turns compressed air into smooth quarter-turn rotation. Air to port A drives the pistons outwards and turns the output counter-clockwise; air to port B drives them inwards and turns it clockwise, with the opposite port exhausting each time.

HYLINE-K is double-acting, so the valve is powered open and powered closed. Fifteen sizes cover 9.2 Nm to 3,509 Nm at 6 bar, and torque is published for supply pressures from 3 to 8 bar, so you can size from the pressure you actually have on site.

Our established ranges already cover the vast majority of quarter-turn duties. Where yours is genuinely different, we engineer the mounting, controls or package around it.

Choose HYLINE-K for

  • On-off and isolation duties on quarter-turn valves
  • Sites with a dependable compressed air supply
  • Corrosive and offshore locations, with stainless steel bodies and C5M coating
  • Packages with solenoid valves, switchboxes and positioners on the NAMUR interfaces

At a glance

HYLINE-K

Mechanism
Opposed-piston rack and pinion
Action
Double-acting, powered both ways
Sizes
15, AKD-032 to AKD-270
Torque
9.2 to 3,509 Nm at 6 bar
Supply
Published from 3 to 8 bar
Body
Aluminium alloy, 304 or 316 stainless steel
Interfaces
ISO 5211 F03 to F16, NAMUR
Rotation
90° standard, 120° or 180° options

Sizing

Size a HYLINE-K in three steps

Start from the torque your valve needs and add a 20% safety margin. Then turn to the output torque table on the HYLINE-K data sheet (repeated in the technical data below), take the column for your lowest air supply pressure, and read down it to the first model that gives more torque than your figure.

How to read the HYLINE-K output torque table: take your valve torque plus 20%, find the column for your lowest supply pressure, and read down to the first model with more torqueModelbarbarbarbar2Your columnLowest supply pressure1Valve torquePlus a 20% margin3Your sizeFirst model above
How to read the output torque table on the data sheet and on this page. Models run from the smallest size at the top to the largest at the bottom.
  • 1. Valve torqueStart with the torque your valve needs and add 20%
  • 2. Pressure columnIn the data sheet torque table, use the column for your lowest supply pressure
  • 3. First model aboveRead down that column and choose the first model with more torque

Advantages

Why choose a HYLINE-K

A simple, field-proven mechanism, with the body, coating and seal choices that let one range serve general industrial duties and offshore installations alike.

Smaller HYLINE-K rack and pinion actuator, showing the NAMUR accessory interface on top

Opposed-piston design

Two opposed pistons drive the output for smooth, repeatable 90° rotation.

Powered both ways

Air drives the valve open and closed, so movement is positive in both directions.

Body choices

Aluminium alloy as standard, with 304 and 316 stainless steel bodies for corrosive sites.

Offshore coating

C5M offshore coating and other protective finishes for exposed locations.

Seal options

NBR as standard, Viton for high temperatures and HNBR for low temperatures.

ISO 5211 mounting

Flange patterns from F03 to F16 across the range for direct valve mounting.

NAMUR interfaces

Standard NAMUR accessory and air interfaces for solenoid valves, switchboxes and positioners.

Cycle tested

Tested to 1 million cycles.

Extended travel

0-120° and 0-180° operation available alongside the standard 90°.

Technical data

HYLINE-K technical specifications

Fifteen sizes, all double-acting. Torque is published at eight supply pressures from 3 to 8 bar.

General data

PropertyHYLINE-K
TypeDouble-acting pneumatic rack and pinion actuator, opposed pistons
Sizes15, AKD-032 to AKD-270
Output torque9.2 Nm to 3,509 Nm at 6 bar; 4.6 Nm to 4,679 Nm across 3 to 8 bar
Rotation90° standard; 0-120° and 0-180° options
BodyAluminium alloy; 304 or 316 stainless steel
CoatingC5M offshore coating and other protective coatings
SealsNBR standard; Viton (high temperature) or HNBR (low temperature)
Valve mountingISO 5211, F03 to F16
Accessory and air interfacesNAMUR
Air connection1/8" to 1/2", by size
Weight0.47 kg to 96.9 kg
Cycle lifeTested to 1 million cycles

Output torque by supply pressure

Output torque in Nm at each air supply pressure, in bar.

Model3 bar4 bar4.5 bar5 bar5.5 bar6 bar7 bar8 bar
AKD-0324.66.16.97.68.49.210.712.2
AKD-0407.010.011.012.013.014.017.019.0
AKD-05212.016.018.020.021.923.927.931.9
AKD-06321.929.232.836.540.143.851.158.4
AKD-07530.140.145.150.255.260.270.280.3
AKD-08347.062.770.578.486.294.1109.7125.4
AKD-09267.790.3101.6112.9124.1135.4158180.6
AKD-10599.0132149165182198231265
AKD-125151201226251276301351401
AKD-140257342385428470513599684
AKD-1603995325996657327989311,064
AKD-1906388519581,0641,1701,2771,4901,702
AKD-2107981,0641,1971,3301,4631,5961,8622,128
AKD-2401,1541,5391,7311,9242,1162,3092,6933,078
AKD-2701,7552,3392,6322,9243,2173,5094,0944,679

Weight, operating time, air volume and interfaces

Operating time in seconds for each direction of travel. Air volume in litres for each stroke.

ModelISO 5211Air connectionWeight kg90° to 0° s0° to 90° sAir, opening LAir, closing L
AKD-032F031/8"0.470.400.300.030.04
AKD-040F05 / F031/4"1.000.500.500.080.11
AKD-052F05 / F031/4"1.380.530.600.120.16
AKD-063F07 / F051/4"2.030.580.660.210.23
AKD-075F07 / F051/4"2.700.640.720.300.34
AKD-083F07 / F051/4"3.130.730.830.430.47
AKD-092F07 / F051/4"4.600.861.000.640.73
AKD-105F10 / F071/4"6.771.301.350.950.88
AKD-125F10 / F071/4"8.901.792.401.601.40
AKD-140F12 / F101/4"13.252.102.502.502.20
AKD-160F12 / F101/4"20.142.603.933.703.20
AKD-190F141/4"31.303.454.555.905.40
AKD-210F141/4"46.804.355.507.507.50
AKD-240F161/4" or 3/8" (std)67.288.338.4011.009.00
AKD-270F161/2"96.908.5310.9017.0014.00

Source: HYLINE-K pneumatic double-acting actuators data sheet, Advanced Actuators, August 2026. Images are representative. The final model number and configuration are confirmed when you order.

Options

Build the model code

Every HYLINE-K part number follows one pattern: body, model, coating, seals, options.

Part of the codeCodeMeaning
BodyAKDAluminium alloy body (standard)
BodyAKD-S4304 stainless steel body
BodyAKD-S6316 stainless steel body
Model032 to 270Actuator size, 15 sizes
CoatingC5MOffshore coating
SealsStandardNBR
SealsHTViton, for high temperatures
SealsLTHNBR, for low temperatures
Options0-120° or 0-180°Extended rotation instead of the standard 90°

Pneumatic control package

Solenoid valves, filter regulators and other accessories fit the NAMUR interfaces. See instrumentation and controls.

Feedback and positioning

HYTRACK or HYCONTROL on the NAMUR interface for feedback and closed-loop control.

Fail-safe duties

HYLINE-K is double-acting. Where a valve must close or open on loss of air, HYLINE-R spring-return is the fail-safe choice.

Control and feedback

Ready for feedback and positioning

NAMUR interfaces on every HYLINE-K take our own instrumentation, so the actuator, feedback and positioner can all come from one supplier.

HYTRACK position transmitter in a stainless steel enclosure

Position transmitter, A-HR

HYTRACK

High-resolution position feedback for on-off and modulating valves.

  • 4-20 mA, 24 V DC two-wire loop powered, with HART 7
  • 12-bit contactless sensor and simple end-position calibration, 0 to 360°
  • Mechanical or proximity limit switch options
  • 316L stainless steel housing, IP66 and NEMA 4X
HYCONTROL valve positioner with display and a stainless steel Ex terminal box

Positioner, A-HC and A-HCR

HYCONTROL

Closed-loop positioning for modulating duties on hydraulic and pneumatic actuators.

  • 4-20 mA command and 4-20 mA feedback, with HART 7
  • Simple two-step calibration and manual operation
  • Stepping mode, fault relay outputs and performance monitoring
  • A-HCR has HYTRACK feedback built in

Valves and applications

Where HYLINE-K works

HYLINE-K suits quarter-turn duties from general industrial service to offshore, wherever a dependable compressed air supply is available.

Ball valvesButterfly valvesPlug valves

Hazardous area? Tell us the zone, gas group and temperature class, and we will confirm the certification for your exact unit.

Not sure it is the right fit? For larger valves or spring-return fail-safe duty, see HYLINE-R Scotch yoke. With no air supply, see the HYLINE-E electric range.

  • Oil and gas

    On-off and isolation duties on process and utility lines, onshore and offshore.

  • Chemical and petrochemical

    Stainless steel bodies and seal options for corrosive and demanding process conditions.

  • Water and wastewater

    Isolation valves at treatment works and pumping stations.

  • Power generation

    Quarter-turn isolation on auxiliary and utility systems.

  • Marine and offshore

    C5M offshore coating and stainless steel bodies for exposed decks.

  • General industrial

    Everyday quarter-turn automation wherever compressed air is available.

Certification

Specified to suit your project

Certification depends on the specification, the components used and the area classification. Tell us what your project calls for and we will confirm the marks for your unit when we quote.

ISO 9001 certified quality managementISO 45001 certified health and safety managementEx mark for equipment for explosive atmospheresIECEx certification schemeUKCA markingINMETRO certification for BrazilIP66 ingress protection ratingIP68 ingress protection ratingNEMA 4X enclosure rating

Downloads

HYLINE-K downloads

  • HYLINE-K data sheet

    PDF, 1.8 MB. Features, torque from 3 to 8 bar, ordering code and dimensions.

    Download

  • Advanced Actuators overview brochure

    PDF, 5.4 MB. The full actuator, power unit and instrumentation range.

    Download

Sizing help

Not sure which size?

Send the valve type, size and torque with your minimum air pressure, and we will come back with the right size.

Already installed

Servicing and repairs

Overhaul, repair and spares for actuators in service, with commissioning support on site.

Size your HYLINE-K

Looking for a HYLINE-K or a price?

We just need three details.

Replacing one? Send the model code from the nameplate and a photo, and we will work from those.

  1. Valve

    Type and size, with its torque if you have it.

  2. Air supply

    Your minimum supply pressure. No air on site? We will look at HYLINE-E.

  3. Environment

    Body, coating and seal needs, the temperature range and the area classification.

Email us your detailsCall +44 (0)1535 655151

Prefer us to call you? Request a callback.

FAQs

HYLINE-K questions

Anything else? Call +44 (0)1535 655151 or email sales@advanced-actuators.com.

How does a rack and pinion actuator work?

Two opposed pistons drive the output. On HYLINE-K, air to port A forces the pistons outwards and turns the valve counter-clockwise; air to port B forces them inwards and turns it clockwise, with the other port exhausting.

How do I size a HYLINE-K?

Start with the torque your valve needs and add a 20% safety margin. In the output torque table on the HYLINE-K data sheet (also in the technical data on this page), take the column for your lowest air supply pressure and read down it to the first model with more torque than your figure. For example, a valve needing 400 Nm becomes 480 Nm; in the 5 bar column the first model above that is AKD-160, at 665 Nm.

Rack and pinion or Scotch yoke: which do I need?

A rack and pinion gives a broadly even torque through the stroke and suits a wide range of quarter-turn valves. A Scotch yoke gives more torque at the ends of the stroke, which suits larger, high-torque valves. We offer both: HYLINE-K and HYLINE-R.

Is HYLINE-K fail-safe?

HYLINE-K is double-acting: it is powered open and powered closed, and stays where it is if the air supply is lost. For duties that must close or open on loss of air, choose HYLINE-R spring-return.

Which body and seals should I choose?

Aluminium alloy suits most general duties. Choose 304 or 316 stainless steel, or the C5M offshore coating, for corrosive and exposed sites. Seals are NBR as standard, Viton for high temperatures and HNBR for low temperatures.

How much air does a HYLINE-K use?

Air per minute = (opening plus closing air volume) x (supply pressure in kPa + 101.3) / 101.3 x cycles per minute. An AKD-160 at 6 bar, cycling once a minute, uses about 48 litres per minute.

Can I fit a solenoid valve, switchbox or positioner?

Yes. NAMUR accessory and air interfaces take solenoid valves, switchboxes and positioners, including our HYTRACK transmitter and HYCONTROL positioner.

Is HYLINE-K suitable for hazardous areas?

Tell us the zone, gas group and temperature class, and we will confirm the certification for your exact unit before you order.

Back to top