HYFLOW smart hydraulic pumping units explained

HYFLOW is a compact hydraulic power unit that can be mounted with a valve actuator. It combines a 24 V DC brushless motor with hydraulic control to provide a local source of flow and pressure. A suitable actuator can therefore operate without a separate site hydraulic power unit and distribution network.

The value of an integrated pumping unit lies in how it fits the valve duty: the oil volume needed, load, stroke time, control arrangement and available electrical supply. Compact dimensions and low standby consumption are useful only when the package also delivers the required movement.

What makes a pumping unit smart

Smart describes the control and communication capabilities provided with the equipment. HYFLOW offers closed-loop flow and pressure control, with 4-20 mA and HART 7 communication listed for the range. Positioning and feedback options allow it to form part of a complete actuator control package.

Flow control affects movement speed. Pressure capability determines whether enough force or torque is available against the valve load. Valve-position control adds a further function: comparing the required position with measured position and correcting the actuator movement.

These functions need to be specified together. A communication interface does not, on its own, establish which measurements and diagnostics the plant will receive.

Current published HYFLOW data

ItemPublished range information
Electrical supply24 V DC
Motor400 W brushless motor
Supply current2 to 20 A, with duty-specific starting and running requirements to be confirmed
Flow range0.4 to 3 litres per minute
Pressure range70 to 207 bar
Steady-state consumptionBelow 1 W for the stated HYFLOW condition
Housing316L stainless steel
Environmental protectionIP66 and NEMA 4X

These figures describe the published range, not a promise that maximum flow and maximum pressure are available simultaneously. The supplier must confirm the flow-pressure operating point, duty and electrical demand for the selected package.

Moving and holding position

The pumping unit supplies hydraulic flow when the actuator needs to move. In a package designed for low-power holding, the pump can stop once the demanded position is reached, while the hydraulic circuit restricts unwanted movement.

The exact holding arrangement and control response depend on the build. Holding performance should be specified against load, temperature and permitted drift. Our fail-safe actuation guide explains the distinction between holding position and providing fail movement.

The below-1 W figure should not be used as the standby total for every assembled valve package. Controllers, transmitters, energised solenoids, heaters and communication equipment can add consumption. Obtain the whole-package power schedule for battery or solar sizing.

Fail-safe and manual operation

HYFLOW can be used in a package with a specified fail-safe function. A spring or accumulator may provide the energy for movement after supply loss, with the circuit directing that energy to the actuator. A powered command response and a true loss-of-power movement are different requirements.

If manual hydraulic operation is needed, request the hand-pump arrangement and its operating instructions with the quotation. Confirm travel effort, access and the effect of the manual controls on the fail-safe function. A hand pump should not be assumed to be included in every unit.

Local power or a central hydraulic supply

A local unit can reduce external hydraulic pipework and make a new standalone valve easier to integrate. It can also limit the hydraulic effects of a fault to a smaller part of the installation.

A central HPU may still suit a group of valves, particularly where infrastructure already exists or the design includes redundancy. Separate local pumps do not remove common dependencies such as a shared DC supply, controls or environmental exposure.

The choice should compare installed pipework, utilities, access, maintenance and the required response to faults. A hydraulic power unit can be local or central; the terminology does not prescribe its size or number of users.

Specifying HYFLOW with an actuator

HYFLOW is offered as the self-contained power option for HYLINE and HYLINE-R. Compatibility with another hydraulic actuator requires an assessment of displacement, pressure, flow, circuit and controls.

Send our team the actuator details, required stroke time, operating pressure and frequency, fail action and available 24 V DC supply. Include environmental requirements and any existing control-system interface.

Discuss your valve application

Contact our engineers to discuss your valve duty and application requirements.

Email our engineersCall +44 (0)1535 655151

Back to top