A hydraulic rotary actuator uses fluid pressure to turn a valve shaft. For a quarter-turn ball, plug or butterfly valve, the actuator normally moves through 90 degrees. Hydraulic pressure can provide substantial torque from a compact cylinder, making it useful where the valve load is high or installation space is limited.
The important selection figure is the available torque across the whole movement, under the specified supply and failure conditions. A single maximum-torque figure is not enough to establish suitability.
How a Scotch yoke produces rotary movement
A Scotch yoke converts the cylinder’s linear movement into rotation of the output shaft. Its mechanical advantage changes with position, so the available torque changes through the stroke.
A symmetrical yoke commonly produces higher torque towards the ends of travel than near the middle. That can suit valves with demanding breakaway or seating loads. It does not mean that every valve’s peak load occurs at an end position: flow-induced torque can be important during travel, particularly on some butterfly-valve duties.
Compare the manufacturer’s actuator torque curve with the valve manufacturer’s load curve in both directions. Our Scotch yoke and rack-and-pinion comparison explains the mechanical differences.
Double-acting and spring-return arrangements
A double-acting actuator uses pressure for both opening and closing. Its behaviour following supply loss depends on the control and holding circuit, leakage and external load. Double-acting is not, by itself, a guarantee of fail-in-place performance.
A spring-return actuator uses pressure in one direction and stored spring energy in the other. Specify whether the required fail movement is open or closed, and compare the net powered torque and spring-return torque with the valve load throughout travel.
An accumulator can also provide stored hydraulic energy in a suitably designed system. Its capacity and circuit arrangement must be assessed for the particular duty. See our fail-safe actuation guide.
The checks that determine selection
| Check | Information needed |
|---|---|
| Valve torque | Breakaway, running and seating loads in both directions at the service conditions |
| Minimum available torque | Actuator output at minimum supply, including opposing pressure and spring load |
| Maximum applied torque | Output at maximum possible pressure compared with stem and mounting limits |
| Failure response | Required movement or holding behaviour for each specified fault |
| Travel time | Opening, closing and fail-stroke requirements with test conditions |
| Mechanical interface | Flange, shaft, coupling, bracket, orientation and space for accessories |
Apply the project or valve-maker allowance explicitly. Confirm whether the valve’s quoted torque already includes it, and avoid relying on nominal supply pressure where the actuator may see less during movement.
Ring-main or local hydraulic power
An existing hydraulic network can supply several actuators, subject to available pressure, flow and the operating sequence. Consider simultaneous movements and the effect of a shared supply fault.
A self-contained package provides local hydraulic power at the valve. It can reduce distribution pipework, but the electrical supply, local maintenance access and any shared control dependencies still require consideration. Neither arrangement is automatically the more reliable choice for every installation.
Offshore and exposed installations
Specify the environment for the assembled package, including its controls and fittings. Salt exposure, deluge, wash-down, vibration and access for maintenance can all influence the build. If immersion is possible, state the depth and duration rather than treating an ingress rating as a general subsea approval.
Hazardous-area requirements are another separate part of the specification. Provide the area classification, required protection level, temperature conditions and applicable project approvals. A certificate for an accessory should not be taken as approval of every possible actuator assembly.
HYLINE-R hydraulic options
HYLINE-R is our Scotch yoke range for hydraulic or pneumatic supply, with double-acting and spring-return configurations. A local HYFLOW unit can provide a self-contained hydraulic package.
The published HYLINE-R pneumatic torque tables use a stated air pressure. They should not be presented as hydraulic performance data. For hydraulic selection, we provide the output figures for the proposed pressure, action and configuration.
What to send for a quotation
Send the valve torque data and allowable stem torque, hydraulic supply range, required fail action, timing requirements and mounting information. Include the site environment and controls. Our team can then assess the complete valve and actuator duty rather than select from a headline torque alone.
Discuss your valve application
Contact our engineers to discuss your valve duty and application requirements.